Omron E2E2-X5C1-M1 has 3 recorded cross-reference matches across 1 manufacturer. Compare the listed alternatives and check their source notes before selecting a replacement.
Turck BI5-G18-AN6X-B1341 versus Omron E2E2-X5C1-M1:
PDF page 17, table row 15. Printed type Prox; FORM=Close; FUNCTION=Direct. Direct means exact in that dimension; Close means similar with minor differences; Alternate means a different solution. Omron recommends candidate replacements for the Turck item; dimensions, characteristics or sensing distance can differ. Historical chart, date not printed; clerical errors possible. Manufacturer-listed directional selection candidate; verify current specifications and application suitability. Bidirectional discovery does not imply symmetric technical interchangeability. No transitive equivalence inferred.
Turck BI5-P18-AN6X-B2341 versus Omron E2E2-X5C1-M1:
PDF page 18, table row 28. Printed type Prox; FORM=Close; FUNCTION=Direct. Direct means exact in that dimension; Close means similar with minor differences; Alternate means a different solution. Omron recommends candidate replacements for the Turck item; dimensions, characteristics or sensing distance can differ. Historical chart, date not printed; clerical errors possible. Manufacturer-listed directional selection candidate; verify current specifications and application suitability. Bidirectional discovery does not imply symmetric technical interchangeability. No transitive equivalence inferred.
Turck BI5-P18-AN6X-B2341/S100 versus Omron E2E2-X5C1-M1:
PDF page 18, table row 29. Printed type Prox; FORM=Close; FUNCTION=Direct. Direct means exact in that dimension; Close means similar with minor differences; Alternate means a different solution. Omron recommends candidate replacements for the Turck item; dimensions, characteristics or sensing distance can differ. Historical chart, date not printed; clerical errors possible. Manufacturer-listed directional selection candidate; verify current specifications and application suitability. Bidirectional discovery does not imply symmetric technical interchangeability. No transitive equivalence inferred.
Counts describe recorded relationships, not stock, sales, testing or independent qualification. Manufacturer-and-part identities remain separate. Indexing dates do not establish current specifications or availability.
Check current manufacturer documents and electrical, mechanical, environmental and application requirements before selecting a replacement.