PART CROSS REFERENCE · INDUSTRIAL FILTERS

PA10032BALDWIN cross reference & alternatives

BALDWIN →

BALDWIN PA10032 has 52 recorded cross-reference matches across 34 manufacturers. Research equivalent, alternate or similar parts using the listed candidates, and check their source notes before selecting a replacement.

52Direct crosses
Updating2nd-degree candidates · Unverified
34alternate manufacturers
1reference sources
COMPARE YOUR OPTIONS

PA10032 equivalents, alternate parts & cross references

Recorded alternatives for this lookup direction. Each source may carry conditions or differences.

AIRMATIC

IF0845

Technical notes
Technical notes

AIRMATIC IF0845 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 61, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
BECK/ARNLEY

422217

Technical notes
Technical notes

BECK/ARNLEY 422217 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 107, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
CARQUEST

89103

Technical notes
Technical notes

CARQUEST 89103 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 155, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
CARQUEST

90296P

Technical notes
Technical notes

CARQUEST 90296P versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 155, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
CHAMPION

CAF1907P

Technical notes
Technical notes

CHAMPION CAF1907P versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 189, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
CORTECO

80004567

Technical notes
Technical notes

CORTECO 80004567 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 226, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
DENSO

4536044

Technical notes
Technical notes

DENSO 4536044 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 246, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
ECOGARD

XC10189

Technical notes
Technical notes

ECOGARD XC10189 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 297, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

FRAM CV11811 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 386, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

FRAM FPCF11811 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 387, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

FRAM PCF11811 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 390, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
GK INDUSTRIES

CF1270

Technical notes
Technical notes

GK INDUSTRIES CF1270 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 403, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
GRAINGER

52AZ63

Technical notes
Technical notes

GRAINGER 52AZ63 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 445, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

GUR C1756E versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 463, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
HENGST

E3903LI

Technical notes
Technical notes

HENGST E3903LI versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 486, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
INTERFIL

CFI2410

Technical notes
Technical notes

INTERFIL CFI2410 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 520, column 5; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
KNECHT

LA1139

Technical notes
Technical notes

KNECHT LA1139 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 557, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
LUBER-FINER

CAF1907C

Technical notes
Technical notes

LUBER-FINER CAF1907C versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 596, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
LUBER-FINER

CAF1907P

Technical notes
Technical notes

LUBER-FINER CAF1907P versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 596, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
MAGNETI MARELLI

1AMAC907AA

Technical notes
Technical notes

MAGNETI MARELLI 1AMAC907AA versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 615, column 5; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
MAHLE

LA1139

Technical notes
Technical notes

MAHLE LA1139 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 618, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
MANN+HUMMEL

CU24009

Technical notes
Technical notes

MANN+HUMMEL CU24009 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 628, column 5; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

MAZDA K031V9030 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 643, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

MAZDA KD4561J6X versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 643, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

MAZDA KD4561J6X9U versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 643, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

MAZDA KD4561J6XMV versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 643, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

MAZDA KR1161J6X versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 643, column 5; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

MAZDA MP111KD45 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 643, column 5; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
MECAFILTER

ELR7328

Technical notes
Technical notes

MECAFILTER ELR7328 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 645, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
MICRO-GARD

4083

Technical notes
Technical notes

MICRO-GARD 4083 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 652, column 5; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
NAPA GOLD

224103

Technical notes
Technical notes

NAPA GOLD 224103 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 682, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
NAPA GOLD

4103

Technical notes
Technical notes

NAPA GOLD 4103 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 687, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
NAPA PROSELECT

224103

Technical notes
Technical notes

NAPA PROSELECT 224103 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 695, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PARTS PLUS

CAF4103

Technical notes
Technical notes

PARTS PLUS CAF4103 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 733, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PENTIUS

PHB8175

Technical notes
Technical notes

PENTIUS PHB8175 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 739, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PERFORMAX

PC123

Technical notes
Technical notes

PERFORMAX PC123 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 740, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PREMIUM GUARD

CFI2410

Technical notes
Technical notes

PREMIUM GUARD CFI2410 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 751, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PREMIUM GUARD

PC4103

Technical notes
Technical notes

PREMIUM GUARD PC4103 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 753, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PREMIUM GUARD

PC4103HX

Technical notes
Technical notes

PREMIUM GUARD PC4103HX versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 753, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PREMIUM GUARD

PC4103X

Technical notes
Technical notes

PREMIUM GUARD PC4103X versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 753, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PREMIUM GUARD

PC6098

Technical notes
Technical notes

PREMIUM GUARD PC6098 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 753, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PRIME GUARD

PCF24103

Technical notes
Technical notes

PRIME GUARD PCF24103 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 755, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
PRIME GUARD

PCF8175

Technical notes
Technical notes

PRIME GUARD PCF8175 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 755, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
SAKURA

CA17160

Technical notes
Technical notes

SAKURA CA17160 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 814, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
SERVICE CHAMP

C38175

Technical notes
Technical notes

SERVICE CHAMP C38175 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 831, column 4; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
SERVICE CHAMP

CAF1907

Technical notes
Technical notes

SERVICE CHAMP CAF1907 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 831, column 5; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

STP C11811 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 853, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

STP CAF1907M versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 853, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

STP CAF1907MHP versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 853, column 3; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
VALVOLINE

VCA1175

Technical notes
Technical notes

VALVOLINE VCA1175 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 904, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
WIX FILTRON

CF11811

Technical notes
Technical notes

WIX FILTRON CF11811 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 970, column 1; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
Technical notes
Technical notes

WIX 24103 versus BALDWIN PA10032:

Baldwin Form 560-24 Manufacturers' Cross-Reference, printed page 942, column 2; one clean same-line ordering-code row. Baldwin states the guide is for general reference and that application decisions remain the installer's responsibility. Manufacturer-listed comparison, not independently certified drop-in equivalence. Verify current application, dimensions and mounting, connections/threads, seals and gasket needs, filter medium, filtration and flow ratings, bypass/collapse pressure, temperature, approvals and any required housing or accessories. Original-to-Baldwin recommendation; reverse lookup retains this orientation and does not approve reverse substitution. No competitor-to-competitor inference. Rows carrying gasket/housing symbols, alternatives, variations, conditions, clean-and-reuse or lost-UL notes were held out of this batch.

Source: Baldwin Form 560-24 Manufacturers' Cross-Reference → (Form 560-24; supersedes Form 560-22; copyright 2024)
EXPLORE INDIRECT CONNECTIONS

Second-degree candidates

Find additional research candidates through a shared connecting part. Each result is labeled Second-degree candidate · Unverified and shows both recorded source relationships.

Two recorded crosses do not establish a verified equivalent. Compare current specifications, interfaces, ratings, cable requirements and the same PCB footprint or panel fit before substitution. Candidate counts are separate from direct-cross and part totals.

PA10032 replacement and similar-part research

Looking for an equivalent or alternate to BALDWIN PA10032? The 52 recorded candidates above link to individual part pages and the evidence behind each relationship.

A recorded cross reference does not establish a drop-in replacement. Compare current datasheets, package or mounting dimensions, pinout, electrical ratings and operating conditions for your application. Similar parts can differ in critical specifications.

Browse more BALDWIN cross references → · Request help researching this part →

MANUFACTURER DOCUMENTATION

BALDWIN PA10032 specifications & datasheets

No part-specific datasheet link has been verified in this record. Document-search links are provided to help locate current specifications.

TRACE THE REFERENCE

Source coverage & limitations

Counts describe recorded relationships, not stock, sales, testing or independent qualification. Manufacturer-and-part identities remain separate. Indexing dates do not establish current specifications or availability.

Check current manufacturer documents and electrical, mechanical, environmental and application requirements before selecting a replacement.

How ExactCross handles cross-reference data →